Q.PEAK DUO TESTED TO WITHSTAND 1-IN-500-YEAR CYCLONE

Diletta Darrigo09 Oct 2019
Cyclone-Testing Q.PEAK DUO-G5
Q CELLS’ Newest High-Performance Panel Undergoes Cyclone Testing at James Cook University’s Cyclone Testing Station in Queensland


In 260km/h wind speeds, cyclones have the ability to reduce a building to tatters and turn almost any object not secured to a structure into a dangerous projectile. When it comes to solar panels on rooftops, ensuring the durability of the panel so that it actually performs throughout the warranted period is the ultimate goal for any manufacturer.

Given Australia’s cyclone-prone climates, cyclone testing for building materials, including solar panels, is an absolute imperative in order to provide safety and peace of mind to the community and Q CELLS customers. 

Testing The New Q.PEAK DUO
In August, Q CELLS’ brand new Q.PEAK DUO-G5 became the most recent solar module in the Q CELLS product family to be tested to the most extreme cyclone conditions. Cyclone testing is important in order to ensure they will perform as expected in the worst of Australian conditions.

Q CELLS tests the Australian product family at Australia’s renown James Cook University (JCU) Cyclone Testing Station in Townsville, QLD. JCU is Australia’s premier cyclone testing centre due to their thorough and comprehensive testing and over 40 years of experience.

Every model of Q CELLS’ 60-cell or 120-cell size family undergoes cyclone testing here. For the first time this year, Q CELLS will also be conducting cyclone testing for 72-cell and 144-cell panels.
Image

  Q.PEAK DUO EXCEEDED THE DESIGN PRESSURE FOR THE WHOLE SYSTEM. IT IS GOOD TO SEE A SOLAR MODULE UNDERGO THIS THOROUGH AND RIGOROUS TESTING   

IEC Standards and Cyclones
IEC standards require solar panels to withstand 2400Pa and most reputable module manufacturers claim that their panels can withstand this amount. However, IEC fails to take the safety factor (a precautionary measurement to ensure that any unforeseen high risk/low probability events are still accounted for without affecting the safety of the installation) into account.

IEC standards also do not require manufacturers to show the actual strength of the module – unlike the testing done at James Cook University which thoroughly tests the reliability of a system as a whole.
Image
JCU Cyclone Testing Rig of Q CELLS Q.PEAK DUO
James Cook University Cyclone Testing Station Laboratory
Testing the System: Static & Cyclic Tests
Here at JCU, Q CELLS panels, including Q.PEAK DUO-G5, undergo two different tests designed for cyclone durability. These two tests are: a static test and a cyclic test. Senior Engineer, Simon Ingham, said Q.PEAK DUO-G5 exceeded the design pressure for the whole system in this latest round of testing. He also notes that it is good to see a solar module undergo this thorough and rigorous testing. 

To simulate the effect of cyclonic winds on a solar system, the panels are placed face down. Then, pressure is administered from above. According to Ingham, “In a cyclone, it’s like the wind is trying to pick your house up by the roof. When you have solar panels on your roof, it’s then trying to pick your house up by the solar panels.” This imparts enormous uplift forces on the solar panel. When forces like this exist, the panels could fail and become a dangerous projectile.


Static Testing
The first test, known as the static test, uses a hydraulic rig to push down on Styrofoam blocks. The Styrofoam blocks then push down on the underside of the solar panels in a simulation of uplift. Three solar panels clamp and attached to racking in accordance to Q CELLS’ installation guidelines. This is to ensure the realest conditions to an installed-system. “Testing the whole system” is the mantra of JCU Cyclone Testing Station which has been in operation for over 40 years.

Over the course of about 45 minutes in the static test, pressures increase until the system fails. A fail point could be when glass shatters and dislodges, a connection releases, or the panel otherwise breaks. The final pressure is recorded and input to the final test report.

Cyclic Testing
The main difference between the static and cyclic test is in the static test, the panels endure increasing pressure and each incremental pressure is held for one minute until the system fails. In a cyclic test, the module is subject to a low-high-low pressure profile. This means the pressure gradually increases to the peak over 10,361 pressure cycles. The high pressures, when combined with the cyclic stress on the system, simulates the cyclonic wind stresses upon the modules. This simulation mimics pressures being greatest near the eye wall, then waning as it passes.

Unlike in the static test, wherein the panel is supposed to eventually fail to determine its ultimate strength, the cyclic test is pass-or-fail. It is the hope of the manufacturer that the panels will be able to withstand the cyclic test without breaking. Q.PEAK DUO-G5 passed the cyclic test.
Image